RBD — 25 kV Rail Traction Chain
Six-month traction availability for a regional line: grid supply point, paralleled feeder substations, overhead line, pantograph and a 3-of-4 traction converter group on the unit.
Make it your own.
title "25 kV traction power chain — regional line"
mission 4380h
block grid "National grid supply point" mtbf: 26000h mttr: 3h
block ssA "Feeder substation A" mtbf: 70000h mttr: 8h
block ssB "Feeder substation B" mtbf: 70000h mttr: 8h
block ohle "Overhead line equipment" mtbf: 18000h mttr: 6h
block panto "Pantograph" mtbf: 30000h mttr: 2h
block conv1 "Traction converter, bogie 1" mtbf: 40000h mttr: 12h
block conv2 "Traction converter, bogie 2" mtbf: 40000h mttr: 12h
block conv3 "Traction converter, bogie 3" mtbf: 40000h mttr: 12h
block conv4 "Traction converter, bogie 4" mtbf: 40000h mttr: 12h
block aux "Auxiliary power unit" mtbf: 55000h mttr: 6h
block tcms "Train control and management" mtbf: 90000h mttr: 4h
# 3-of-4 converters: the unit keeps timetable speed on three bogies, so
# losing one is a defect, not a failure.
series {
grid
parallel { ssA; ssB }
ohle
panto
kofn 3 of 4 { conv1; conv2; conv3; conv4 }
aux
tcms
}