Risk Matrix — Biosafety Level 2 Laboratory Risk Assessment
A BSL-2 risk assessment for a fictional viral-vector core covering biological, chemical, physical and ergonomic hazards: controls cut exposure from 87 to 40 (−54%), move eight of nine hazards down a band and leave every residual risk within the Medium appetite, the lentiviral needlestick highest at Medium 6. Illustrative register.
Make it your own.
title "Viral vector core facility — BSL-2 laboratory risk assessment"
subtitle "Lentiviral vector production and in-vivo work · biological, chemical and physical hazards"
likelihood-levels: Rare, Unlikely, Possible, Likely, Almost certain
impact-levels: Negligible (no treatment), Minor (first aid), Moderate (medical treatment), Major (lost-time injury or seroconversion risk), Severe (fatality or permanent harm)
thresholds: 4, 9, 16
appetite: Medium
note "Illustrative assessment for a fictional facility; ratings are examples for training, not a local risk assessment."
risk B1 "Needlestick with lentiviral vector during animal injection"
category: Biological
owner: Facility Manager
likelihood: 3
impact: 4
control "Safety-engineered needles and a no-resheathing rule"
control "Sharps bins at the point of use"
control "Occupational health post-exposure protocol"
residual: 2x3
risk B2 "Aerosol release from a failed centrifuge tube"
category: Biological
owner: Biological Safety Officer
likelihood: 3
impact: 4
control "Sealed safety cups opened only inside the microbiological safety cabinet"
residual: 1x4
risk B3 "Asphyxiation in the liquid nitrogen cryostore"
category: Physical
owner: Facility Manager
likelihood: 2
impact: 5
control "Oxygen-depletion monitor alarming at 19.5%"
control "No lone working in the cryostore"
residual: 1x5
risk B4 "Hydrofluoric acid burn during glass etching"
category: Chemical
owner: Chemical Safety Officer
likelihood: 2
impact: 5
control "HF-specific SOP with calcium gluconate gel at the bench"
control "Double nitrile and neoprene gloves with a face shield"
residual: 1x4
risk B5 "Repetitive strain from manual pipetting"
category: Ergonomic
owner: Facility Manager
likelihood: 4
impact: 2
control "Electronic pipettes and task rotation every 90 minutes"
residual: 3x2
risk B6 "Vector stock spilled outside the safety cabinet"
category: Biological
owner: Biological Safety Officer
likelihood: 3
impact: 3
control "Spill kits with 1% Virkon and annual spill drills"
residual: 2x2
risk B7 "Formaldehyde exposure during tissue fixation"
category: Chemical
owner: Chemical Safety Officer
likelihood: 3
impact: 3
control "Fixation only in a ducted fume hood"
control "Annual personal exposure monitoring"
residual: 2x2
risk B8 "Autoclave cycle fails to inactivate waste"
category: Biological
owner: Biological Safety Officer
likelihood: 3
impact: 3
control "Weekly biological indicators and a chart recorder on every cycle"
residual: 1x3
risk B9 "Safety cabinet airflow failure goes unnoticed"
category: Biological
owner: Facility Manager
likelihood: 2
impact: 4
control "Airflow alarm and annual KI-discus containment test"
residual: 1x4