Cold-Chain Temperature Excursion (Vaccine Depot)
How a depot quarantines, assesses and dispositions a vaccine pallet after a 2-8 C excursion alarm.
Rendering…
Make it your own.
flowchart TD
A[Data logger alarms - 2 to 8 C envelope breached] --> B[Quarantine the pallet, do not discard]
B --> C[Download the full logger trace, not just the alarm point]
C --> D{Which direction was the breach?}
D -->|Above 8 C| E[Sum cumulative time above 8 C across the whole cold-chain life]
D -->|Below 2 C| F[Check the freeze indicator and the shake test where applicable]
E --> G{Inside the manufacturer stability budget?}
F --> G
G -->|Yes| H[Release with a documented deviation]
G -->|No| I[Refer to the responsible person]
I --> J{Concession possible on stability data?}
J -->|Yes| H
J -->|No| K[Destroy under witness and notify the regulator if a shortage results]
H --> L[Close the deviation and trend the failure mode monthly]
K --> L
L --> M[Requalify the route or the packout if the mode repeats]